Sometimes iatrogenic complications are the hardest to treat. In this case, single balloon enteroscopy was used to locate the source of bleeding in a patient with an abnormal video capsule endoscopy after pancreas transplant. A non-bleeding ulcer was seen and biopsied. Bleeding control was ultimately needed.